Documents & Standards

Documents and standards provide information on product performance, indoor air quality and environmental impacts. Each document is assessed within the scope of the product or facility it identifies.

Low-emissions certification

Intertek Clean Air GOLD

Assesses low-emission criteria that support indoor air quality. It compares the volatile organic compounds emitted by the product against the relevant limits.

Environmental Product Declaration

EPD

Describes the product’s environmental impacts throughout its life cycle using verified data. It supports environmental assessment in material and project selection; it is not an environmental superiority label.

Indoor-air emissions report

Testing against M1 criteria

Compares the product’s indoor air emissions against M1 limits. It demonstrates the emissions performance of the tested sample; the test report is not itself an M1 classification certificate.

Declaration of Performance

CE / EN 14041

Sets out the declared performance of the flooring under the applicable standard. It covers properties such as reaction to fire, slip resistance and formaldehyde emissions for the specified product.

Technical values

Values apply to the product and test conditions defined in the relevant technical data sheet. Sound insulation values are assessed together with the building assembly in which the flooring is installed.

PropertyStandardValueWhat does it mean?
Use classificationEN 16511Class 23 / 33Indicates residential (23) and commercial (33) use classes.
Reaction to fireEN 13501-1Bfl-s1Indicates limited contribution to fire and low smoke production.
Abrasion resistanceEN 16511≥ 3000 cyclesIndicates resistance in the abrasion test.
Impact resistanceEN 16511≥ 1800 mmIndicates tested resistance to impact from a falling object.
Residual indentationEN 16511≤ 0.01 mmIndicates the indentation depth remaining after the load is removed.
Dimensional stabilityEN 16511≤ 0.15%Indicates dimensional change under test conditions.
Thickness swellingEN 16511No swellingIndicates no increase in thickness under test conditions.
Stain resistanceEN 438-2Class 5Indicates no visible surface change after contact with the tested substances.
Micro-scratch resistanceEN 16094MSR-A1 / MSR-B1Classification for gloss change and visible scratches in micro-scratch testing.
Castor chair resistanceISO 4918No change after 25,000 cyclesIndicates no surface change after the stated number of cycles in castor chair testing.
Slip resistanceEN 13893DSIndicates compliance with the dynamic friction requirement on a dry floor.
Electrostatic behaviourEN 1815AntistaticIndicates limited static electricity generation under test conditions.
Thermal resistanceEN 126670.034 m²K/WIndicates the floor’s resistance to heat transfer.
Underfloor heatingData sheetMax. 27 °CThe floor surface temperature must not exceed this value.
Impact Insulation ClassASTM E492-09IIC 62 (calculated)A system rating for impact sound transmission to the floor below; a higher value indicates better insulation.
Sound Transmission ClassASTM E90-09STC 60 (calculated)A system rating for airborne sound transmission; a higher value indicates better insulation.

Understanding production standards

Management-system certificates and social audits address a manufacturing facility’s processes. They are assessed separately from product performance reports.

ISO 9001 — Quality management

A management system standard addressing production consistency, quality control and continual improvement. It covers facility processes and does not certify the performance of individual products.

ISO 14001 — Environmental management

Addresses systematic management of the environmental impacts of production. It is distinct from a product EPD.

ISO 45001 — Occupational health & safety

Addresses workplace risk management and occupational health and safety processes.

amfori BSCI — Social compliance

A facility audit covering working conditions and social compliance. It is not a certification or product document; audit results are reported as a rating from A to E. Scope and results are assessed through the current audit record.

These headings explain the scope of management standards and social compliance audits. Current document status and scope are assessed separately for the relevant product or production facility.

STONEKS / DOCUMENTS

Catalogues

Explore our SPC and natural stone collections in the catalogues below.

SPC Flooring CollectionEnglish / PDF ↗SPC Wall CollectionEnglish / PDF ↗SPC Skirting CollectionEnglish / PDF ↗SPC Stair CollectionWeb ↗Natural Stone CollectionEnglish / PDF ↗